Bifurcated Terminals bottom and top attachment connection requirements per IPC

For bifurcated terminals, there are 3 connection ways per IPC 620.

1, Side Route Attachments

2, Bottom attachments

3, Top attachments

Today, we will introduce the spec of bottom and top attachments.

info-259-237info-407-237

Target - Class 1,2,3

• Wire insulation does not enter base or posts of terminal.

• Bottom route wire wrap contacts two parallel sides of post

(180°).

• Wire is against base of terminal.

• Top route wire has space between posts filled by using

separate filler or bending the wire double (Figure 4-23 B, C).

info-382-290

Acceptable - Class 1

Process Indicator - Class 2

Defect - Class 3

• Wire insulation enters base or posts of terminal.

• Top route wire is not supported with filler.

• Bottom route wire not wrapped to terminal base or post with

a minimum 90° bend.