Flexible Sleeve Insulation on the soldered wire and terminal inspection criteria per IPC

Target - Class 1,2,3
• Insulation sleeving overlaps the connector terminal (at
arrows) and extends over the wire insulation four wire diameters
(D).
• Insulation sleeving is one wire diameter (D) from the point
where the connector terminal enters the connector insert.

info-416-402

 

Acceptable - Class 1,2,3
• Insulation sleeving overlaps the connector terminal and the
wire insulation by a minimum of two wire diameters, whichever
is smaller.
• Insulation sleeving is more than 50% wire diameter and not
more than two wire diameters from the point where the connector
terminal enters the connector insert.

info-408-338

 

Defect - Class 2,3
• Insulation sleeving is split (A).
• Insulation sleeving overlaps the wire insulation by less than
two wire diameters (B).
• Insulation sleeving is more than two wire diameters from the
point where the connector terminal enters the connector
insert (C).
• Insulation sleeve is loose on the terminal (could slide or
vibrate off, exposing more than the allowed amount of conductor
or terminal) (D).
• Insulation sleeving is less than 50% wire diameter from the
point where the connector terminal enters the connector
insert (A, B, D).

info-435-322