The attenuation of wires is mainly affected by the following factors:

1. Conductor resistance
Metal conductors (such as copper and aluminum) themselves have resistance, and high-frequency signals will experience a decrease in effective cross-sectional area and an increase in resistance due to skin effect.
2. Capacitors and inductors
Long wires form distributed capacitors and inductors, and high-frequency signals are prone to waveform distortion due to energy leakage through capacitors or radiation from inductors.
3. Electromagnetic interference
Electromagnetic fields in the surrounding environment (such as motors and cables) can couple interference signals and reduce signal quality.
4. Aging of insulation materials
High temperature, chemical corrosion, or mechanical damage can damage the insulation layer and accelerate attenuation.
5. Frequency and Cable Structure
High frequency signals exacerbate conductor losses due to skin effect, while dielectric losses increase linearly with frequency.
The outer diameter of the cable, the outer diameter of the inner conductor, and the dielectric constant affect the characteristic impedance, which in turn affects attenuation.
6. Temperature and mechanical stress
The increase in temperature leads to an increase in conductor resistance and dielectric loss; Excessive bending or compression can damage the interior