What is the bridged wire spec in soldering per IPC-A-620?

During wire soldering, the is possibility to cause bridged wire during the process.

How to judge it acceptable or not? Normally we follow IPC spec.

Target - Class 1,2,3

• No birdcaging.

Acceptable - Class 1,2,3

• Wire strands have separation (birdcaging) (see Figure 3-6)

but do not exceed the lesser of:

• One strand diameter or

• Do not extend beyond wire insulation outside diameter.

info-277-226

Acceptable - Class 1

Process Indicator - Class 2

Defect - Class 3

• Wire strands have separation exceeding one strand diameter

but do not extend beyond wire insulation outside diameter.

• The general spiral lay of the strands has not been maintained.

info-280-230