We know the terminals are packed in reels normally, and there is carrier to hold the terminals in the reel. Below picture show the terminals are on a carrier.

When crimping it, we need to cut the terminal from the carrier. There is carrier material residual on the terminal after crimping, if the residual is too much, may affect the terminal application. So IPC-A-620 defined the carrier cutoff tab residual criteria.
Acceptable - Class 1,2,3
• No damage to contact or terminal.
• Cutoff does not prevent complete mating of the contact/terminal.
Process Indicator - Class 2,3
• Cutoff tab length at mating end is greater than 2X its thickness
but does not impede mating.
• Cutoff tab length at wire entry end is greater than 2X its thickness but does not protrude when inserted into connector body.


Defect - Class 1,2,3
• Carrier cutoff tab length is greater than 2X its thickness (Figure 5-43).
• Removal of cutoff tab has damaged contact or terminal.
• Cutoff tab protrudes from connector body when contact has been inserted.
• Mating end cutoff tab prevents complete mating.
• No carrier cutoff tab visible and contact/terminal is damaged.
Note: Contact/terminal needs to meet form, fit, function and reliability requirements. A trial mating may be required for final acceptance.