What's is the Flat Cable –Connector Skew and Lateral Position spec in IPC-A-620?
IDC connector position skew and lateral are normal defect in flat cable manufacturing, Top-cable follow below IPC-A-620 spec to control it.
Target - Class 1,2,3
• Connector is aligned perpendicular to the edge of the flat cable.
• Cable end is flush along the entire length of the outside edge of the connector.
• All conductors are centered within the v-notch of the connector contacts
.
Acceptable - Class 1,2,3
• Connector is aligned so that all conductors are centered in their respective v-notches of the cable.

Defect - Class 1,2,3
• Connector misalignment precludes contact of all wires to the IDC contacts.
• Connector misalignment permits shorting of conductors in the IDC contact area.
• Connector misalignment precludes assembly of connector cover.
• Connector misalignment causes wire damage during crimping.
• Face of the cable is not parallel to the face of the connector (Figure 6-14).