What’s the IPC spec of Discrete Wire Termination – End Connectors?

What's the IPC spec of Discrete Wire Termination – End Connectors?

 

Below is the IPC spec for such IDC connection.

Target - Class 1,2,3

• Wire fully seated into the contact.

• Wire extends at least 50% of the distance between the contact edge and the back wall of the connector.

 

info-468-326

Acceptable - Class 1,2,3

• Wire touches back wall with slight deformation but the top of the wire does not rise above the back wall.

 

• Portions of bare conductor are visible but no bare conductor extends outside the connector body.

 

• Exposed conductors do not violate minimum design electrical clearance.

 

info-463-325

Defect - Class 1,2,3

• Wire stripped or partially stripped before being inserted into the connector.

 • Wire not within retaining barbs.

• Two wires into a single contact unless the contact or connector specifications indicate that this is acceptable.

• Deformation of the connector body due to wires with oversize insulation.

• Insufficient stress relief on wires entering connector.

• Wire size does not meet connector parameters.

• Wire not fully seated in both sets of v-notches of the IDC contact.

• The wire extends less than one wire diameter out of the rear contact.

• Broken retaining barbs on the connector.