For terminal crimping, the conductor brush area is also an important factor. Good conductor brush shape and length will provide enough terminal crimping retention strength.
As a professional manufacture, Top-cable always follow IPC-A-620 to control the conductor brush during the crimping process. Below is the spec.
Target - Class 1,2,3
• The conductor strands protrude slightly past the end of the conductor crimp forming a ''conductor brush.''
• The conductor strands forming the brush are kept together as a group and not flared out

Acceptable - Class 1
Process Indicator - Class 2,3
• Conductor strands not protruding past but flush with the end of the conductor crimp area of the contact (Figure 5-35(1)).
Acceptable - Class 1,2,3
• Conductor strands flared out but not extending outside of the contact (Figure 5-35 (2)).
• Conductor strands extend past the end of the crimp of insulated terminal.


Acceptable - Class 1
Defect - Class 2,3
• Any conductor strands extending outside of the contact (Figures 5-37, 5-38).
• The conductor strands extend into the mating area of the contact (Figures 5-39, 5-40).
Defect - Class 1,2,3
• Outer insulation of insulated terminal is damaged exposing metal (Figure 5-40).