Feb 23, 2026 Leave a message

What’s the connector damage inspection criteria in IPC/WHMA-A-620?

In cable assembly industry, connector is the most important component, how to inspect and judge the connector damage in the manufacturing? Top-cable always follow IPC/WHMA-A-620

 

Target - Class 1,2,3

• Shell surface is clean, unmarked and undamaged.

• Key or keyways are not distorted or damaged or mispositioned.

info-368-270

Defect - Class 1,2,3

• Shell or positioning keys are damaged or contain deep

scratches or burrs (A).

• Damaged inner or outer ring (out-of-round condition) (B).

• Key width or height has been reduced (C).

• Key is mispositioned (Not Shown).

• Connector shell or body is cracked, fractured or otherwise

damaged.

info-420-321

Send Inquiry

whatsapp

Phone

E-mail

Inquiry