In cable assembly industry, connector is the most important component, how to inspect and judge the connector damage in the manufacturing? Top-cable always follow IPC/WHMA-A-620
Target - Class 1,2,3
• Shell surface is clean, unmarked and undamaged.
• Key or keyways are not distorted or damaged or mispositioned.

Defect - Class 1,2,3
• Shell or positioning keys are damaged or contain deep
scratches or burrs (A).
• Damaged inner or outer ring (out-of-round condition) (B).
• Key width or height has been reduced (C).
• Key is mispositioned (Not Shown).
• Connector shell or body is cracked, fractured or otherwise
damaged.